Using a high precision Master Meter or Prover Tank the meters can be calibrated to a maximum error of + 0.05% and a period of six months for re-calibration, Dynamic SLIP TEST on the meters enables us to predict the mechanical state of meter and permits useful recommendation. When the meter is out of calibration, repair is carried out (with client’s consent) and recalibrated.
We undertake calibration of Prover Tank of all sizes using the Automatic Over flow pipe pipette gravy metrically calibrated to within 0.002% and traceable to international standards. We certify the Prover Tanks at 0.02% accuracy.
The necessity of accurate tank calibration becomes particular evident where tanks are used for Stock Control or Custody Transfer Measurements.
We undertake calibration of Vertical Storage Tanks using Strapping Method in accordance with API 2551 Bottom volumes for Vertical Tanks can be determined by liquid fill or physical floor survey as requested.
Horizontal Tanks, Ship and Barge Tanks can be determined by liquid fill or physical floor survey as requested.
Horizontal Tanks, Ship and Barge Tanks are calibrated by Physical Strapping in accordance with API 255! and 2553 respectively.
We undertake calibration of Road Trucks of Petroleum product in the clients’ premises with our high precision Master or at oil Installation if required using the gantry Meters. The calibration can also be done within our premises (flow Lab)
These are calibrated by liquid fill method, the most accurate method of calibration using our high precision Master Meters. The liquid fill method in determining incremental volume of the tank takes into account the tilt of the tank underground
We undertake calibration of petroleum product dispensing pumps using Our standard measures traceable to international standards for purpose of precise control of product quantities.
The necessity of accurate tank calibration becomes particular evident where tanks are used for Stock Control or Custody Transfer Measurements.
We undertake calibration of Vertical Storage Tanks using Strapping Method in accordance with API 2551 Bottom volumes for Vertical Tanks can be determined by liquid fill or physical floor survey as requested.
Horizontal Tanks, Ship and Barge Tanks can be determined by liquid fill or physical floor survey as requested.
Horizontal Tanks, Ship and Barge Tanks are calibrated by Physical Strapping in accordance with API 255! and 2553 respectively.
Starbest also undergo the calibration of LPG vessels and tank within our customer’s premises to ascertain the quality and quantity of the vessels
Plot 13, Blocks1A, Amuwo Odofin Industrial Layout
Amuwo Odofin
Lagos, Nigeria